Skip to Content

How to design a DOAS unit as sole source heating and cooling

When possible, it makes life easy to have a separate DOAS system from the space HVAC system. In this case, each system has one specific job: -The DOAS’s job is...... Read More

DYK York doesn’t require suction traps for R410a?

When an HVAC system uses POE (Polyolester) oil, which is typical of current R410a systems, suction oil traps are not required* because POE is miscible in R410a in all phases...... Read More

Fan Types- Centrifugal, Axial, Forward Curve, Airfoil. What does it all mean?

The cfm Distributors Inc Applied Systems Group meets every other Monday at 8am for training. This training covers a plethora of topics, but a portion of this training is...... Read More

How to use Fan Laws for design/build retrofits

If you’ve ever had a situation where your HVAC unit had less airflow than expected, you’ve officially had a run-in with the FAN LAWS. The biggest takeaway from this...... Read More

HVAC swimming pool design

Did you know that the HVAC equipment for indoor pool applications should not be installed directly above the swimming pool area? Warm moist air, which might contain airborne chemicals like...... Read More

How do you select and design a custom coil replacement?

Here is a step-by-step process for replacing a custom coil and A) Making sure it fits and B) Making sure it works.Step #1: Gather the physical coil dimensions (more info...... Read More

Can you mix R-410a and R-22 equipment?

“Can you install an R-410a condensing unit matched with an R-22 evaporator coil?”We get asked this question often, so we thought it would be helpful to write a post about...... Read More

How do you fix a humidity problem?

Humidity, the 8th wonder of the world, is a tough nut to crack. Unlike sensible heat transfer, it’s very difficult to measure its movement into buildings through cracks, doorways, and other openings.But,...... Read More

How many tons of air conditioning is this DX or Chilled Water coil?

If you are measuring a Direct Expansion (DX) or Chilled Water coil in the field, or just quoting a replacement coil, you can quickly estimate its nominal tonnage based...... Read More

How much system water per ton of cooling for process chillers?

Did you know that York recommends a MINIMUM of 6 gallons of system water per ton of cooling for process chillers? This is double the amount of water that...... Read More